SONET

Synchronous optical networking

Page issues
Synchronous optical networking (SONET) and synchronous digital hierarchy (SDH) are standardized protocols that transfer multipledigital bit streams synchronously over optical fiber using lasers or highly coherent light fromlight-emitting diodes (LEDs). At lowtransmission rates data can also be transferred via an electrical interface. The method was developed to replace theplesiochronous digital hierarchy (PDH) system for transporting large amounts oftelephone calls and data traffic over the same fiber without synchronization problems.
SONET and SDH, which are essentially the same, were originally designed to transportcircuit mode communications (e.g., DS1, DS3) from a variety of different sources, but they were primarily designed to support real-time, uncompressed, circuit-switched voice encoded in PCM format.[1] The primary difficulty in doing this prior to SONET/SDH was that the synchronization sources of these various circuits were different. This meant that each circuit was actually operating at a slightly different rate and with different phase. SONET/SDH allowed for the simultaneous transport of many different circuits of differing origin within a single framing protocol. SONET/SDH is not a communications protocol in itself, but a transport protocol.
Due to SONET/SDH's essential protocol neutrality and transport-oriented features, SONET/SDH was the obvious choice for transporting the fixed length Asynchronous Transfer Mode (ATM) frames also known as cells. It quickly evolved mapping structures and concatenated payload containers to transport ATM connections. In other words, for ATM (and eventually other protocols such as Ethernet), the internal complex structure previously used to transport circuit-oriented connections was removed and replaced with a large and concatenated frame (such as STS-3c) into which ATM cells, IP packets, or Ethernet frames are placed.
Racks of Alcatel STM-16 SDH add-drop multiplexers
Both SDH and SONET are widely used today: SONET in the United States and Canada, and SDH in the rest of the world. Although the SONET standards were developed before SDH, it is considered a variation of SDH because of SDH's greater worldwide market penetration. SONET is subdivided into four sublayer with some factor such as the path, line, section and physical layer.
The SDH standard was originally defined by the European Telecommunications Standards Institute (ETSI), and is formalised asInternational Telecommunication Union (ITU) standards G.707,[2] G.783,[3] G.784,[4] and G.803.[5][6] The SONET standard was defined by Telcordia[7] and American National Standards Institute (ANSI) standard T1.105.[6][8] which define the set of transmission formats and transmission rates in the range above 51.840 Mbit/s.

Difference from PDHEdit

SDH differs from Plesiochronous Digital Hierarchy (PDH) in that the exact rates that are used to transport the data on SONET/SDH are tightly synchronized across the entire network, using atomic clocks. Thissynchronization system allows entire inter-country networks to operate synchronously, greatly reducing the amount of buffering required between elements in the network. Both SONET and SDH can be used toencapsulate earlier digital transmission standards, such as the PDH standard, or they can be used to directly support either Asynchronous Transfer Mode (ATM) or so-called packet over SONET/SDH (POS) networking. Therefore, it is inaccurate to think of SDH or SONET as communications protocols in and of themselves; they are generic, all-purpose transport containers for moving both voice and data. The basic format of a SONET/SDH signal allows it to carry many different services in its virtual container (VC), because it is bandwidth-flexible.

Protocol overviewEdit

SONET and SDH often use different terms to describe identical features or functions. This can cause confusion and exaggerate their differences. With a few exceptions, SDH can be thought of as a superset of SONET.
SONET is a set of transport containers that allow for delivery of a variety of protocols, including traditional telephony, ATM, Ethernet, and TCP/IP traffic. SONET therefore is not in itself a native communications protocol and should not be confused as being necessarilyconnection-oriented in the way that term is usually used.
The protocol is a heavily multiplexed structure, with the header interleaved between the data in a complex way. This permits the encapsulated data to have its own frame rate and be able to "float around" relative to the SDH/SONET frame structure and rate. This interleaving permits a very low latency for the encapsulated data. Data passing through equipment can be delayed by at most 32 microseconds (µs), compared to a frame rate of 125 Âµs; many competing protocols buffer the data during such transits for at least one frame or packet before sending it on. Extra padding is allowed for the multiplexed data to move within the overall framing, as the data is clocked at a different rate than the frame rate. The protocol is made more complex by the decision to permit this padding at most levels of the multiplexing structure, but it improves all-around performance.

The basic unit of transmissionEdit

The basic unit of framing in SDH is a STM-1(Synchronous Transport Module, level 1), which operates at 155.520 megabits per second (Mbit/s). SONET refers to this basic unit as an STS-3c (Synchronous Transport Signal 3, concatenated). When the STS-3c is carried over OC-3, it is often colloquially referred to as OC-3c, but this is not an official designation within the SONET standard as there is no physical layer (i.e. optical) difference between an STS-3c and 3 STS-1s carried within an OC-3.
SONET offers an additional basic unit of transmission, the STS-1 (Synchronous Transport Signal 1) or OC-1, operating at 51.84 Mbit/s—exactly one third of an STM-1/STS-3c/OC-3c carrier. This speed is dictated by the bandwidth requirements for PCM-encoded telephonic voice signals: at this rate, an STS-1/OC-1 circuit can carry the bandwidth equivalent of a standard DS-3channel, which can carry 672 64-kbit/s voice channels.[1] In SONET, the STS-3c signal is composed of three multiplexed STS-1 signals; the STS-3c may be carried on an OC-3 signal. Some manufacturers also support the SDH equivalent of the STS-1/OC-1, known as STM-0.

FramingEdit

In packet-oriented data transmission, such asEthernet, a packet frame usually consists of aheader and a payload. The header is transmitted first, followed by the payload (and possibly a trailer, such as a CRC). In synchronous optical networking, this is modified slightly. The header is termed theoverhead, and instead of being transmitted before the payload, is interleaved with it during transmission. Part of the overhead is transmitted, then part of the payload, then the next part of the overhead, then the next part of the payload, until the entire frame has been transmitted.
In the case of an STS-1, the frame is 810octets in size, while the STM-1/STS-3c frame is 2,430 octets in size. For STS-1, the frame is transmitted as three octets of overhead, followed by 87 octets of payload. This is repeated nine times, until 810 octets have been transmitted, taking 125 Âµs. In the case of an STS-3c/STM-1, which operates three times faster than an STS-1, nine octets of overhead are transmitted, followed by 261 octets of payload. This is also repeated nine times until 2,430 octets have been transmitted, also taking 125 Âµs. For both SONET and SDH, this is often represented by displaying the frame graphically: as a block of 90 columns and nine rows for STS-1, and 270 columns and nine rows for STM1/STS-3c. This representation aligns all the overhead columns, so the overhead appears as a contiguous block, as does the payload.
The internal structure of the overhead and payload within the frame differs slightly between SONET and SDH, and different terms are used in the standards to describe these structures. Their standards are extremely similar in implementation, making it easy to interoperate between SDH and SONET at any given bandwidth.
In practice, the terms STS-1 and OC-1 are sometimes used interchangeably, though the OC designation refers to the signal in its optical form. It is therefore incorrect to say that an OC-3 contains 3 OC-1s: an OC-3 can be said to contain 3 STS-1s.

SDH frameEdit

 
An STM-1 frame. The first nine columns contain the overhead and the pointers. For the sake of simplicity, the frame is shown as a rectangular structure of 270 columns and nine rows but the protocol does not transmit the bytes in this order.
 
For the sake of simplicity, the frame is shown as a rectangular structure of 270 columns and nine rows. The first three rows and nine columns contain regenerator section overhead (RSOH) and the last five rows and nine columns contain multiplex section overhead (MSOH). The fourth row from the top contains pointers.
The Synchronous Transport Module, level 1 (STM-1) frame is the basic transmission format for SDH—the first level of the synchronous digital hierarchy. The STM-1 frame is transmitted in exactly 125 Âµs, therefore, there are 8,000 frames per second on a 155.52 Mbit/s OC-3 fiber-optic circuit.[nb 1] The STM-1 frame consists of overhead and pointers plus information payload. The first nine columns of each frame make up the section overhead and administrative unit pointers, and the last 261 columns make up the information payload. The pointers (H1, H2, H3 bytes) identify administrative units (AU) within the information payload. Thus, an OC-3 circuit can carry 150.336 Mbit/s of payload, after accounting for the overhead.[nb 2]
Carried within the information payload, which has its own frame structure of nine rows and 261 columns, are administrative units identified by pointers. Also within the administrative unit are one or more virtual containers (VCs). VCs contain path overhead and VC payload. The first column is for path overhead; it is followed by the payload container, which can itself carry other containers. Administrative units can have any phase alignment within the STM frame, and this alignment is indicated by the pointer in row four.
The section overhead (SOH) of a STM-1 signal is divided into two parts: the regenerator section overhead (RSOH) and the multiplex section overhead (MSOH). The overheads contain information from the transmission system itself, which is used for a wide range of management functions, such as monitoring transmission quality, detecting failures, managing alarms, data communication channels, service channels, etc.
The STM frame is continuous and is transmitted in a serial fashion: byte-by-byte, row-by-row.

Transport overheadEdit

The transport overhead is used for signaling and measuring transmission error rates, and is composed as follows:
Section overhead
Called regenerator section overhead (RSOH) in SDH terminology: 27 octets containing information about the frame structure required by the terminal equipment.
Line overhead
Called multiplex section overhead (MSOH) in SDH: 45 octets containing information about error correction and Automatic Protection Switching messages (e.g., alarms and maintenance messages) as may be required within the network. The error correction is included for STM-16 and above.[9]
Administrative unit (AU) pointer
Points to the location of the J1 byte in the payload (the first byte in the virtual container).[10]

Path virtual envelopeEdit

Data transmitted from end to end is referred to as path data. It is composed of two components:
Payload overhead (POH)
9 octets used for end-to-end signaling and error measurement.
Payload
User data (774 bytes for STM-0/STS-1, or 2,430 octets for STM-1/STS-3c)
For STS-1, the payload is referred to as thesynchronous payload envelope (SPE), which in turn has 18 stuffing bytes, leading to the STS-1 payload capacity of 756 bytes.[11]
The STS-1 payload is designed to carry a full PDH DS3 frame. When the DS3 enters a SONET network, path overhead is added, and that SONET network element (NE) is said to be a path generator and terminator. The SONET NE is line terminating if it processes the line overhead. Note that wherever the line or path is terminated, the section is terminated also. SONET regenerators terminate the section, but not the paths or line.
An STS-1 payload can also be subdivided into seven virtual tributary groups (VTGs). Each VTG can then be subdivided into four VT1.5signals, each of which can carry a PDH DS1signal. A VTG may instead be subdivided into three VT2 signals, each of which can carry a PDH E1 signal. The SDH equivalent of a VTG is a TUG-2; VT1.5 is equivalent to VC-11, and VT2 is equivalent to VC-12.
Three STS-1 signals may be multiplexed bytime-division multiplexing to form the next level of the SONET hierarchy, the OC-3 (STS-3), running at 155.52 Mbit/s. The signal is multiplexed by interleaving the bytes of the three STS-1 frames to form the STS-3 frame, containing 2,430 bytes and transmitted in 125 Âµs.
Higher-speed circuits are formed by successively aggregating multiples of slower circuits, their speed always being immediately apparent from their designation. For example, four STS-3 or AU4 signals can be aggregated to form a 622.08 Mbit/s signal designatedOC-12 or STM-4.
The highest rate commonly deployed is theOC-768 or STM-256 circuit, which operates at rate of just under 38.5 Gbit/s.[12] Where fiber exhaustion is a concern, multiple SONET signals can be transported over multiple wavelengths on a single fiber pair by means of wavelength-division multiplexing, including dense wavelength-division multiplexing (DWDM) and coarse wavelength-division multiplexing (CWDM). DWDM circuits are the basis for all modern submarine communications cable systems and other long-haul circuits.

SONET/SDH and relationship to 10 Gigabit EthernetEdit

Another type of high-speed data networking circuit is 10 Gigabit Ethernet (10GbE). The Gigabit Ethernet Alliance created two 10 Gigabit Ethernet variants: a local area variant (LAN PHY) with a line rate of 10.3125 Gbit/s, and a wide area variant (WAN PHY) with the same line rate as OC-192/STM-64 (9,953,280 kbit/s)[13]. The WAN PHY variant encapsulates Ethernet data using a lightweight SDH/SONET frame, so as to be compatible at a low level with equipment designed to carry SDH/SONET signals, whereas the LAN PHY variant encapsulates Ethernet data using 64B/66B line coding.
However, 10 Gigabit Ethernet does not explicitly provide any interoperability at the bitstream level with other SDH/SONET systems. This differs from WDM system transponders, including both coarse and dense wavelength-division multiplexing systems (CWDM and DWDM) that currently support OC-192 SONET signals, which can normally support thin-SONET–framed 10 Gigabit Ethernet.

SONET/SDH data ratesEdit

SONET/SDH Designations and bandwidths
SONET Optical Carrier levelSONET frame formatSDH level and frame formatPayload bandwidth[nb 3](kbit/s)Line rate (kbit/s)
OC-1STS-1STM-050,11251,840
OC-3STS-3STM-1150,336155,520
OC-12STS-12STM-4601,344622,080
OC-24STS-241,202,6881,244,160
OC-48STS-48STM-162,405,3762,488,320
OC-192STS-192STM-649,621,5049,953,280
OC-768STS-768STM-25638,486,01639,813,120
User throughput must not deduct path overhead from the payload bandwidth, but path-overhead bandwidth is variable based on the types of cross-connects built across the optical system.
Note that the data-rate progression starts at 155 Mbit/s and increases by multiples of four. The only exception is OC-24, which is standardized in ANSI T1.105, but not a SDH standard rate in ITU-T G.707.[2][8] Other rates, such as OC-9, OC-18, OC-36, OC-96, and OC-1536, are defined but not commonly deployed; most are considered orphaned rates.[1][14][15]